Normal Status Lights - Carrier Access Adit 600 - VOIP Voice

On the Adit, Anything Red is an Issue

Probable Failures

Light
Status
Action to take

T1-1

SOLID RED

T1 is down. Call the carrier.

MAJOR/MINOR

SOLID RED

 T1 could have taken a power surge. Call the carrier.

CRD

NOT SOLID GREEN

Voice over IP card failure. Call the carrier.

 

TDM Controller - This is the T1 Card.

Light

Status

Description

MAJOR OR MINOR

OFF

No alarms present

RED / YELLOW

  Red = Major alarm       Yellow = Minor alarm

LOCAL

OFF

Remote mode (DIP switches disabled)

GREEN

Local mode (DIP switches enabled)

ACO

OFF

Normal mode.  No alarms are being suppressed.

YELLOW

Alarm cutoff active. One or more active alarms suppressed.

T1-1 OR T1-2

OFF

Off line

GREEN

Normal

RED

 Loss of Signal (LOS) detected

YELLOW

 Bipolar Violation (BPV) detected

FLASHING GREEN

Loopback active

FLASHING RED

Loss of Frame (LOF) or Alarm Indication Signal (AIS) detected

FLASHING YELLOW

Yellow alarm (Remote Alarm Indication) detected.

 

CMG Router

LED

Status

Description

CRD

Off

Loss of power

Green

No current alarms

Red

Alarm state active. See alarm log for cause

Red Flashing

Self-test or Boot in-process

Yellow Flashing

Card is saving data to flash RAM, do not power down

VOIP

Off

No active VoIP calls or if the MGCP protocol is optioned down

Green

Active VoIP calls

Red

Call agent unreachable

Yellow

Insufficient VoIP resources to complete call or during initialization process

LNK

Off

No Ethernet link

Green

Good Ethernet link

10/100

 Off

10 Mb Ethernet

Green

100 Mb Ethernet

TX/RX

 Off

No Ethernet transmit activity

Green

Current Ethernet TX/RX activity

Yellow

Current Ethernet TX/RX collision

Infotel Systems - Richmond, Virginia - Business Telephone Systems, Voice & Data Networks, Cabling, Carrier Services  804-266-6600