Reported trouble |
Probable cause |
How TESTCALLS can help |
|
Static on
the telephone line. Calls occasionally disconnect. It does not always
happen. |
Bad copper pair
on a line in your outbound hunt group. Problem appears random to user as
they don't always get this line when making outbound calls. |
Calls special
test module connected on site and listens for unexpected disconnect.
Tracks which dialed number failed the most. |
|
Installed new
phone system/voice mail system. Callers occasionally hear incorrect
automated attendant message that was recorded upon
install.. |
Central office
based voicemail service was never canceled when new telephone system was
installed. |
Turn off new
voicemail system. Call your 8 line hunt 9 times simultaneously. Calls will
roll to existing carrier based voicemail system. |
|
Sometimes when I
dial out and get no dial tone. |
Dead line
"hole" in POTS line hunt group has been accessed. |
Calls each line
late at night to verify answer via automated attendant. |
|
Some calls
ring past the operator. |
Unexpected
overflow or intercept programmed into PBX. |
Makes a large
volume of TESTCALLS to the main number to expose overflow. |
|
4 port expansion
to 4 port automated attendant (AA) does not cure occasional busy AA. |
Ports 5 - 8 not
properly installed and thus don't answer. |
Run 3am
TESTCALLS job of 9 simultaneous TESTCALLS to AA. Should get "AA"
and 1 "BUSY" |
|
Phone company
installed lines 7 & 8 to existing 6 line hunt group but still getting
busy signal. |
Phone company
installed lines but failed to add them to the existing hunt group. |
Make 9
simultaneous TESTCALLS. Should get 8 answers and a busy. |
|
Plumber's remote
call forward (RCF) numbers all point to main office. Receives reports of busy
signals to RCF but receptionist at main office states many lines are
idle. |
One or more RCF
numbers does not have sufficient forwarding paths to the main office.
Should be three paths per RCF. |
Run 3am
TESTCALLS job of 4 simultaneous calls to each RCF. Should get three
"AA" and 1 busy for each test. |
|
T1 voice calls
occasionally drop or have static. Problem is "random". T1 loop
back tests run clean. |
Not random at
all. Channels 1 - 16 work fine. Channels 17 - 24 fail but call volume does
not always reach this level. |
Run several sets
of 3am high volume TESTCALLS test with 2 second call spacing to special
test DID on PBX. Set ACD or UCD queue message to answer these calls with a
TONE MODULE tone. TESTCALLS will report simultaneous call volume level
that fails. |
|
Ported many
telephone numbers to another carrier. After port, getting complaints
from customers of un answered calls and modem tones answering calls. |
Some numbers did
not port. Other numbers ported to wrong location. |
Before porting,
run a daytime and a 3am profile on the numbers and save the results. Run
again as soon as numbers port. Compare the files for discrepancies. |
|
Changed
carriers and now get reports of some calls not ringing through. |
Old carrier or
new carrier did not set database "triggers" correctly. |
Instruct
TESTCALLS to make simultaneous calls via 3 separate carriers. |
|
Ordered 100 new
DID numbers. Must verify NEW DID numbers work before ordering
business cards. |
Point all new
numbers to automated attendant or special tone device attached to SLT port
and make TESTCALLS. |
TESTCALLS calls
all numbers and verifies they answer as expected. |